Details
Application
1. Purposed
a) For DC-DC signal isolating only.
b) For dual or triple DC-DC signal output values.
c) For many various small sensor signal to a standard analog output.
d) For industrial control application.
2. Measured signals
a) Voltage or Current.
b) AC or DC
3. Measuring range :For industrial system, the signal should very small such as mV, mA etc., The measuring output ranges are determined as required.
4. Input range :The meter input range can be accept from minimum mV to maximum V as required. Input can be accepted various and floating signal, and the terminals are all isolated from the bottom case, aux. power and input/output circuit.
5. Output range: AC&M has wide output range for available, various analogs 4~20mA or 1~5V etc..
6. Operation environment: The meter can be used under normal room temperature from -5’C to +55’C and relative humidity between 20 to 95%.
DC Isolation (TWD)
Class 0.1% – DC Isolation OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Dual Aux. Power 85/265V AC/DC
Current Loop (TWS)
Class 0.1% – Current Loop Isolation OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Input 4~20mA (2 Wire)
Dual Aux. Power 85/265V AC/DC
RTD Isolating (TWR)
Class 0.1% – RTD Isolation OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Input PT 100 (3 Wire)
Dual Aux. Power 85/265V AC/DC
Thermocouple (TWT)
Class 0.1% – Thermocouple Isolation OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Input K,E,J,T,R,S,B Type
Dual Aux. Power 85V/265V AC/DC
Frequency to DC (TWF)
Class 0.1% – Frequency to DC Isolation OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Input via Open Collector, Voltage Pulses, Contacts
Dual Aux. Power 85V/265V AC/DC
Potentiometer (TWP)
Class 0.1% – Potentiometer, Level, Position OR Conversion Transmitter
Single Input – Single Output
Single Input – Dual Output
Input via 200 ~ 10K Ohms
Dual Aux. Power 85V/265V AC/DC
DC Alarm (TAD)
Class 0.1% – Digital Contact Meter with Isolation and Conversion Transmitter
DC input – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Current Loop (TAS)
Class 0.1% – Digital current Loop Meter with Isolation and Conversion Transmitter
DC input via DC 4~20mA (2 Wire)
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
RTD (TAR)
Class 0.1% – Digital RTD Meter with Isolation and Conversion Transmitter
Input PT100 (3 Wire) – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Thermocouple (TAT)
Class 0.1% – Digital Thermocouple Meter with Isolation and Conversion Transmitter
Input K,E,J,T,R,S,B type – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Potentiometer (TAP)
Class 0.1% – Digital Potentiometr with Isolation and Conversion Transmitter
Input 200 ~ 10K Ohms – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Load Cell, Strain Gauge (TAB)
Class 0.1% – Digital Load cell, Strain Gauge Transmitter
Input DC mV – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Calculas (TAA)
Class 0.1% – Digital Calculas Alarm Transmitter
Input DC mV or mA.
Function as an Adder, Subtractor, Multiplier etc
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 85V/265V AC/DC
Customized
Customized Isolating Transmitter
If you have specific requirements for input, display, contact, signalling.
Our factory can customize to your specific need when provided details.